This is a water treatment method of collecting contaminated ingredients such as oil, and
COD contained in effluent by separating and condensing such liquid substance by use of
membrane modules. No coagulant is used. There is no generation of sludge.
Treated water can be reused and recycled.

ySUF-4Az

REDUCE EFFLUMENT TO 1/20

Condensing effluent reduces generation of waste substances
depending on concentration of effluent.

COAGULANT TREATMENT IS UNNECESSARY

No use of chemical allows easier operation control.

CLEAN WORK ENVIRONMENT

Direct concentration of effluent by filter membrane keeps
working environment clean.

FLOOR SPACE SAVING

Compact unit design reduces floor space.




CUTTING OIL EFFLUENT DATA
Condense Multiplication 10
Before After
PH 9.4 9.1
BOD (mg / Liter) 2000 450
COD (mg / Liter) 3100 200
n-Hex (mg / Liter) 600 12
Appearance Milk-white Transparent
* Water soluble coolant effluent
* Die cast mold agent effluent
* Aged alkaline degreasing liquid
* Copper Rolling oil
* Rolling oil and various emulsion type effluent
(Based on Sinto's test data)

Model SUF-2A SUF-4A SUF-8A
Effluent volume 1m3/day 2m3/day 4m3/day
UF Membrane module 1.62~2pcs 1.62~2pcs 1.62~2pcs
Dimensions (mm) 2940v~1030k
~1800g
2940v~1230k
~1800g
2940v~1230k
~1800g
Power consumption (50/60Hz) 1.8KW / 1.4jv 3.0KW / 2.2jv 3.4KW / 2.6jv
Specifications are subject to change without notice for improvement.